В сравнении 0
Войти  /  Регистрация

AD5T

(0)
AD5T
Спецификации:

        AD5           AD5T          AD8          AD8T
      







Thermocouple Type
J
J
K
K
Nominal Temperature
0° to 700°
0° to 700°
-100° to 924°
-100° to 924°
Range °C







Nominal Temperature
32° to 1292°
32° to 1292°
-148° to 1695°
-148° to 1695°
Range °F







Over/Under Range
-20° to 1200°
-20° to 1200°
-125° to 1250°
-125° to 1250°
Capability °C







Over/Under Range
- 4° to 2192°
- 4° to 2192°
-193° to 2282°
-193° to 2282°
Capability °F







Average
0.18 °C
0.18 °C
± 0.25 °C
± 0.25 °C
Resolution
  (0 to 700 °C)
  (0 to 700 °C)
  (-100 to 924 °C)
  (-100 to 924 °C)


0.36 °C
0.36 °C
± 0.5 °C
± 0.5 °C


  (700 to 1200 °C)
  (700 to 1200 °C)
  (924 to 1250 °C)
  (924 to 1250 °C)
Accuracy*
± 3 °C (0 to 700 °C)
± 3 °C (0 to 700 °C)
± 3 °C (-100 to 924 °C)
± 3 °C (-100 to 924 °C)
Repeatability
± 1 °C
± 1 °C
± 1 °C
± 1 °C
Power
17 mA at +15 (+/- 0.25) VDC
35 mA at +15 (+/- 0.25) VDC
17 mA at +15 (+/- 0.25) VDC
35 mA at +15 (+/- 0.25) VDC
Requirements
12 mA at -15 +/- 0.25 VDC
35 mA at -15 (+/- 0.25) VDC
12 mA at -15 (+/- 0.25) VDC
35 mA at -15 (+/- 0.25) VDC
        







*Accuracy may be improved by the use of "Set Offset" and "Set Gain" commands in the OPTOMUX command set.


Документация:
0439_Std_Thermocouple_data_sheet / 0891_CE_Declaration_Low_Voltage / 0892_CE_Declaration_EMC / 1648_RoHS_Stmt_Compliance_Lead-Free_Prods_list
Модуль аналогового ввода термопары AD5T типа J обеспечивает единый оптически изолированный канал преобразования температуры в цифровое значение.

В дополнение к оптической изоляции этот модуль включает в себя переходную канальную изоляцию 4000 В перем. тока, что устраняет любые проблемы с контуром заземления.

Этот модуль монтируется на монтажной стойке G1, например, PB16AH.

ad8.jpg
Спецификации

        AD5           AD5T          AD8          AD8T
      







Thermocouple Type
J
J
K
K
Nominal Temperature
0° to 700°
0° to 700°
-100° to 924°
-100° to 924°
Range °C







Nominal Temperature
32° to 1292°
32° to 1292°
-148° to 1695°
-148° to 1695°
Range °F







Over/Under Range
-20° to 1200°
-20° to 1200°
-125° to 1250°
-125° to 1250°
Capability °C







Over/Under Range
- 4° to 2192°
- 4° to 2192°
-193° to 2282°
-193° to 2282°
Capability °F







Average
0.18 °C
0.18 °C
± 0.25 °C
± 0.25 °C
Resolution
  (0 to 700 °C)
  (0 to 700 °C)
  (-100 to 924 °C)
  (-100 to 924 °C)


0.36 °C
0.36 °C
± 0.5 °C
± 0.5 °C


  (700 to 1200 °C)
  (700 to 1200 °C)
  (924 to 1250 °C)
  (924 to 1250 °C)
Accuracy*
± 3 °C (0 to 700 °C)
± 3 °C (0 to 700 °C)
± 3 °C (-100 to 924 °C)
± 3 °C (-100 to 924 °C)
Repeatability
± 1 °C
± 1 °C
± 1 °C
± 1 °C
Power
17 mA at +15 (+/- 0.25) VDC
35 mA at +15 (+/- 0.25) VDC
17 mA at +15 (+/- 0.25) VDC
35 mA at +15 (+/- 0.25) VDC
Requirements
12 mA at -15 +/- 0.25 VDC
35 mA at -15 (+/- 0.25) VDC
12 mA at -15 (+/- 0.25) VDC
35 mA at -15 (+/- 0.25) VDC
        







*Accuracy may be improved by the use of "Set Offset" and "Set Gain" commands in the OPTOMUX command set.


Наличие на складах

0439_Std_Thermocouple_data_sheet Detail
0891_CE_Declaration_Low_Voltage Detail
0892_CE_Declaration_EMC Detail
1648_RoHS_Stmt_Compliance_Lead-Free_Prods_list Detail